– A load cel calibrator with a max. capacity of 15 tf
– Designed for calibration of various tensile and compression load cells, including load cells used with specialized auxiliary equipment, with capacities of up to 150 kN
– Designed in accordance with ISO 376, ISO – 7500, OIML R 60
– Equipped with an ODR system for automatic reading and recording of measurement data in the software
– Servo-electromechanical drive system using ball screws
– Test capabilities: tensile, compression, cyclic, and creep testing
– AC servo motor and servo drive with closed-loop control system
– Fully computerized control system featuring DSP-based technology and USB and RS-232 communication interface, compatible with different PC type configuration
– Windows-based JADOO Controller software for implementing test procedures in accordance with OIML requirements
– Capable of generating calibration tables and test reports in accordance with ISO 7500, OIML R 60, ISIRI6 3724, ISO 376, ISO 7500, ASTM E4
– Test speed range: 0.001-500 mm/min
– Equipped with specialized fixtures for convenient mounting of tensile and compression load cells
– Equipped with a portable control keypad
– High test repeatability and measurement accuracy
– Easy operation and tabletop design

To meet the calibration and verification requirements of various industries and metrology laboratories, SANTAM has designed and manufactured Reference Standard Measurement Machines (RSMM) in capacities ranging from 5 to 200 tf. These machines are designed to generate controlled compressive forces for the calibration and verification of reference load cells using overhead-mounted reference load cells. The machines were initially developed for the Weight Unit of Iran National Standards Organization (INSO).
The machine applies a controlled and precisely measured force to the device under test (DUT), while its output is compared with that of a reference standard load cell accompanied by a valid calibration certificate stating the calibration results and their associated measurement uncertainties.
The system is designed in accordance with ISO 7500, ISO 376, and OIML R 60. It features a servo-electromechanical drive system (offering an alternative to conventional hydraulic or deadweight systems). The machine operates automatically, applying precisely controlled forces with high accuracy, while minimizing the need for operator intervention.
Most Outstanding Features of the STM-150LC Calibrator
– Servo-electromechanical force application system comprising precision ball screws, AC servo motor, and servo drive
– Automatic execution of calibration procedures with minimal operator intervention
– Minimization of operator-induced measurement errors
– High-accuracy force application and measurement
– Precise control of loading and unloading speed to minimize overshooting during calibration
– Capability to perform both tensile and compression calibration of load cells
– Equipped with self-aligning fixtures and dedicated connectors
– Dedicated calibration software supporting the implementation of test procedures in accordance with applicable requirements of the International Organization of Legal Metrology standard (OIML)
– Equipped with an optical character recognition (OCR) system for automatically reading load cell display and recording test results in the software
– Equipped with a graduated angular adjustment scale for positioning the load cell at 0°, 120°, 180°, 240°, and 360° during calibration
– Capable of evaluating key metrological characteristics of load cell, including non-linearity, hysteresis, temperature effect on output, and reversibility in accordance with accuracy classesLoad Cell Calibration in Accordance with OIML R 60
– Automatic execution of specialized load cell calibration procedures, including non-linearity, hysteresis, repeatability, and creep testing under sustained, constant load conditions
– Supports the evaluation and calibration of commercial and industrial across different accuracy classes, including classes C3 to C6.

Calibration and Classification of Force-Proving Instruments in Accordance with ISO 376 (For Reference Load Cells and Force Standards)
– Capable of calibrating and classifying reference load cells and other force-proving instruments in high-accuracy classes (class 00, class 0.5, and class 1) by applying precisely controlled loading and unloading cycles to determine metrological characteristics, including interpolation error and reversibility.

Calibration and Verification in Accordance with ISO 7500-1 (For Tensile and Compression Testing Machines)
– Provides the required procedures for calibrating and verifying the force measuring systems of material testing machines, establishing their verified force measuring ranges and determining their accuracy classes (class 0.5, class 1, and class 2).

Generation of Calibration Tables and Test Reports in Accordance with ISO 7500, OIML R 60, ISIRI 3724, ISO 376, and ASTM E4
– Capable of calculating and evaluating various metrological characteristics, including reversibility, repeatability, linearity, hysteresis, absolute error, relative error, combined error, interpolation error, creep, and recovery
– Capable of determining calibration equations and generating reports containing equation coefficients
– Capable of calculating relative expanded uncertainty
– Capable of exporting test results and calibration reports in Microsoft Excel-compatible formats
The calibrator features a servo-electromechanical drive system comprising an AC servo motor, servo drive, and precision ball screw. Force control is implemented through load cell feedback, while displacement control is achieved using encoder feedback. This closed-loop control architecture enables precise regulation of loading conditions and test speed over a wide operating range of 0.001 to 500 mm/min.
Load frame is designed to accommodate both tensile and compression load cells in two separate testing spaces, allowing calibration procedures to be performed in accordance with requirements of the relevant standards.
The calibrator is equipped with a high-precision displacement sensor with a measuring range corresponding to the available crosshead travel. The displacement resolution is 0.1 µm, with a measurement accuracy of ±0.05 mm. The displacement measurement system provides accurate feedback for maintaining stable test speeds over a wide operating range and supports precise control of the applied force.
The system incorporates dedicated software and hardware for the automatic execution of calibration procedures. All stages of force application and control are performed using a closed-loop control system, which continuously monitors the applied force and regulates the loading process to minimize overshooting and prevent the applied force from exceeding the specific target limits.

The calibrator is designed for use in reference laboratories to calibrate and evaluate both tensile and compression load cells by comparison with calibrated reference standard load cells. Calibration procedures can be performed in accordance with applicable OIML requirements, with the dedicated software generating comprehensive calibration reports, including:
– Assessment of the metrological performance of reference standard load cells and load cells under test
– Measurement and evaluation of load cell errors
– Real-time display of running relative error (%)
– Determination of relative error with respect to full scale output (FSO)
– Evaluation of relative error in accordance with ISO-7500
– Reproducibility
– Repeatability
– Linearity
– Relative expanded uncertainty
– Reversibility and hysteresis
– Combined error
– Creep, recovery, and relative zero error

Reviews

There are no reviews yet.

Be the first to review “Load Cell Calibrator – STM-150LC”
To inquire about the product price, copy its code

قبل از ادامه دادن، مطمئن شوید که نام محصول را کپی کرده‌اید

برای دسترسی به این فرم لازم است به حساب کاربری خود در سایت سنتام وارد شوید

سازنده:

شرکت طراحی مهندسی سنتام

استعلام قیمت

درخواست مشاوره

دانلود کاتالوگ

شرایط تحویل حضوری

شرایط تحویل کالا در محل کارخانه

جزییات بیشتر

شرایط ارسال دستگاه

شرایط ارسال دستگاه و حمل آن

جزییات بیشتر

متن آزمایشی

متن آزمایشی

جزییات بیشتر

گارانتی دستگاه

شرایط خدمات پس از فروش

جزییات بیشتر

جزییات بیشتر

– A load cel calibrator with a max. capacity of 15 tf – Designed for calibration of various tensile and compression load cells, including load cells used with specialized auxiliary equipment, with capacities of up to 150 kN – Designed in accordance with ISO 376, ISO – 7500, OIML R 60 – Equipped with an ODR system for automatic reading and recording of measurement data in the software – Servo-electromechanical drive system using ball screws – Test capabilities: tensile, compression, cyclic, and creep testing – AC servo motor and servo drive with closed-loop control system – Fully computerized control system featuring DSP-based technology and USB and RS-232 communication interface, compatible with different PC type configuration – Windows-based JADOO Controller software for implementing test procedures in accordance with OIML requirements – Capable of generating calibration tables and test reports in accordance with ISO 7500, OIML R 60, ISIRI6 3724, ISO 376, ISO 7500, ASTM E4 – Test speed range: 0.001-500 mm/min – Equipped with specialized fixtures for convenient mounting of tensile and compression load cells – Equipped with a portable control keypad – High test repeatability and measurement accuracy – Easy operation and tabletop design
To meet the calibration and verification requirements of various industries and metrology laboratories, SANTAM has designed and manufactured Reference Standard Measurement Machines (RSMM) in capacities ranging from 5 to 200 tf. These machines are designed to generate controlled compressive forces for the calibration and verification of reference load cells using overhead-mounted reference load cells. The machines were initially developed for the Weight Unit of Iran National Standards Organization (INSO). The machine applies a controlled and precisely measured force to the device under test (DUT), while its output is compared with that of a reference standard load cell accompanied by a valid calibration certificate stating the calibration results and their associated measurement uncertainties. The system is designed in accordance with ISO 7500, ISO 376, and OIML R 60. It features a servo-electromechanical drive system (offering an alternative to conventional hydraulic or deadweight systems). The machine operates automatically, applying precisely controlled forces with high accuracy, while minimizing the need for operator intervention.
Most Outstanding Features of the STM-150LC Calibrator – Servo-electromechanical force application system comprising precision ball screws, AC servo motor, and servo drive – Automatic execution of calibration procedures with minimal operator intervention – Minimization of operator-induced measurement errors – High-accuracy force application and measurement – Precise control of loading and unloading speed to minimize overshooting during calibration – Capability to perform both tensile and compression calibration of load cells – Equipped with self-aligning fixtures and dedicated connectors – Dedicated calibration software supporting the implementation of test procedures in accordance with applicable requirements of the International Organization of Legal Metrology standard (OIML) – Equipped with an optical character recognition (OCR) system for automatically reading load cell display and recording test results in the software – Equipped with a graduated angular adjustment scale for positioning the load cell at 0°, 120°, 180°, 240°, and 360° during calibration – Capable of evaluating key metrological characteristics of load cell, including non-linearity, hysteresis, temperature effect on output, and reversibility in accordance with accuracy classesLoad Cell Calibration in Accordance with OIML R 60 – Automatic execution of specialized load cell calibration procedures, including non-linearity, hysteresis, repeatability, and creep testing under sustained, constant load conditions – Supports the evaluation and calibration of commercial and industrial across different accuracy classes, including classes C3 to C6. Calibration and Classification of Force-Proving Instruments in Accordance with ISO 376 (For Reference Load Cells and Force Standards) – Capable of calibrating and classifying reference load cells and other force-proving instruments in high-accuracy classes (class 00, class 0.5, and class 1) by applying precisely controlled loading and unloading cycles to determine metrological characteristics, including interpolation error and reversibility. Calibration and Verification in Accordance with ISO 7500-1 (For Tensile and Compression Testing Machines) – Provides the required procedures for calibrating and verifying the force measuring systems of material testing machines, establishing their verified force measuring ranges and determining their accuracy classes (class 0.5, class 1, and class 2). Generation of Calibration Tables and Test Reports in Accordance with ISO 7500, OIML R 60, ISIRI 3724, ISO 376, and ASTM E4 – Capable of calculating and evaluating various metrological characteristics, including reversibility, repeatability, linearity, hysteresis, absolute error, relative error, combined error, interpolation error, creep, and recovery – Capable of determining calibration equations and generating reports containing equation coefficients – Capable of calculating relative expanded uncertainty – Capable of exporting test results and calibration reports in Microsoft Excel-compatible formats The calibrator features a servo-electromechanical drive system comprising an AC servo motor, servo drive, and precision ball screw. Force control is implemented through load cell feedback, while displacement control is achieved using encoder feedback. This closed-loop control architecture enables precise regulation of loading conditions and test speed over a wide operating range of 0.001 to 500 mm/min. Load frame is designed to accommodate both tensile and compression load cells in two separate testing spaces, allowing calibration procedures to be performed in accordance with requirements of the relevant standards. The calibrator is equipped with a high-precision displacement sensor with a measuring range corresponding to the available crosshead travel. The displacement resolution is 0.1 µm, with a measurement accuracy of ±0.05 mm. The displacement measurement system provides accurate feedback for maintaining stable test speeds over a wide operating range and supports precise control of the applied force. The system incorporates dedicated software and hardware for the automatic execution of calibration procedures. All stages of force application and control are performed using a closed-loop control system, which continuously monitors the applied force and regulates the loading process to minimize overshooting and prevent the applied force from exceeding the specific target limits.

این بخش در حال بروز رسانی می باشد...

[ywtm_content]

این بخش در حال بروز رسانی می باشد...

بازدید یکتا: ... | بازدید کل: ...