{"id":30025,"date":"2024-07-09T06:01:11","date_gmt":"2024-07-09T06:01:11","guid":{"rendered":"https:\/\/www.santam.safirezaban.ir\/%d8%a7%d9%84%d8%b2%d8%a7%d9%85%d8%a7%d8%aa-%d8%b3%d8%a7%d8%ae%d8%aa-%d8%a2%d8%b2%d9%85%d8%a7%db%8c%d8%b4%da%af%d8%a7%d9%87\/"},"modified":"2026-02-15T05:39:42","modified_gmt":"2026-02-15T05:39:42","slug":"laboratory-construction-requirements","status":"publish","type":"page","link":"https:\/\/www.santamco.ir\/en\/laboratory-construction-requirements\/","title":{"rendered":"Laboratory Construction Requirements"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"30025\" class=\"elementor elementor-30025 elementor-25017\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"wd-negative-gap elementor-element elementor-element-38dfa62 e-flex e-con-boxed e-con e-parent\" data-id=\"38dfa62\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-210322a e-con-full e-flex e-con e-child\" data-id=\"210322a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-d6bd9df e-grid e-con-full e-con e-child\" data-id=\"d6bd9df\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-788c848 elementor-widget elementor-widget-heading\" data-id=\"788c848\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Laboratory Construction Requirements<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a8d34d2 e-grid e-con-full e-con e-child\" data-id=\"a8d34d2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77ba571 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"77ba571\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>To construct a laboratory, a few important points must be considered to follow the equipment layout in order to comply with ISO 17025 and avoid any problem, discrepancy, and non-conformity after design and manufacturing.<\/p><p>Such information is provided proportional to lab equipment requirements (mainly SANTAM products). The following information is prepared with respect to the company expertise in sales and commissioning of more than 4500 machines, as well as the problems we faced with during installation, commissioning and sometimes constructing new laboratory.<\/p><p>Along with adhering to safety rules, paying attention to stylish design and efforts to utilize the maximum possible space, as well as easy operation are the most important steps for setting up a laboratory.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-39af345 e-con-full e-flex e-con e-child\" data-id=\"39af345\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-b925275 e-flex e-con-boxed e-con e-parent\" data-id=\"b925275\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-105b2ce wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"105b2ce\" data-element_type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper wd-set-mb reset-last-child wd-title-color-default wd-title-style-default wd-title-size-default text-center\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h4 class=\"woodmart-title-container title wd-fontsize-l\">The Most Important Factors to be Considered in Choosing a Place for a Laboratory<\/h4> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-fa9b09a e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b09a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-d225fcc e-con-full e-flex e-con e-child\" data-id=\"d225fcc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-1e2fe19 e-grid e-con-full e-con e-child\" data-id=\"1e2fe19\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a55c6db elementor-widget elementor-widget-heading\" data-id=\"a55c6db\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">General Principles of Designing a Standard Laboratory<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4cc4919 e-grid e-con-full e-con e-child\" data-id=\"4cc4919\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e4fc67 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"6e4fc67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Any laboratory depending on its application and the volume of current activities should have specific features and facilities. However, the equipment and machines in a lab may vary, but they all have one principle in common, i.e. a QC lab, it should provide proper working conditions for staffs to achieve optimum results and sufficient efficiency.<\/p><p>Attention to factors such as natural and artificial lighting system, air conditioning, humidity, shelves, safety rules, installation place, and so on are the basics of any lab design and construction.<\/p><p>Designing the location of a laboratory is usually the most difficult issues that architecture is dealing with. All requirements and different standards must be observed in such designs, which ultimately lead to development and optimization.<\/p><p>It is necessary to make a 3D design of the lab drawing and review it prior to execution.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f443aae e-con-full e-flex e-con e-child\" data-id=\"f443aae\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-d0264ac e-flex e-con-boxed e-con e-parent\" data-id=\"d0264ac\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-744424b e-con-full e-flex e-con e-child\" data-id=\"744424b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-4622c52 e-grid e-con-full e-con e-child\" data-id=\"4622c52\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09667a6 elementor-widget elementor-widget-heading\" data-id=\"09667a6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Laboratory Layout<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2e0212c e-grid e-con-full e-con e-child\" data-id=\"2e0212c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9872e62 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"9872e62\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>A list of equipment proportional to lab requirements shall be prepared; the equipment standard layout must be in accordance with the manufacturer&#8217;s plan as well as aesthetic and ergonomic considerations. The following points must be considered in layout:<\/p><p style=\"padding-left: 40px;\">Place related devices together<\/p><p style=\"padding-left: 40px;\">Devices must be arranged with a reasonable distance, not too close to each other<\/p><p style=\"padding-left: 40px;\">Devices with high noise and vibration must be away from sensitive devices<\/p><p style=\"padding-left: 40px;\">Sample preparation devices and the machines for performing tests under ambient temperature need to be located in another place<\/p><p style=\"padding-left: 40px;\">In general, 30%-40% of the lab space is allocated to equipment and the rest is considered free space<\/p><p style=\"padding-left: 40px;\">The numbers of staffs, stylish layout space, and equipment selection have direct influence on lab staffs&#8217; performance<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4e7c0b e-con-full e-flex e-con e-child\" data-id=\"d4e7c0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-5ccee7d e-flex e-con-boxed e-con e-parent\" data-id=\"5ccee7d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dbde3f8 e-con-full e-flex e-con e-child\" data-id=\"dbde3f8\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-680edc6 e-grid e-con-full e-con e-child\" data-id=\"680edc6\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d59a4ef elementor-widget elementor-widget-heading\" data-id=\"d59a4ef\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Laboratory Entrance and Device Transportation<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-282c352 e-grid e-con-full e-con e-child\" data-id=\"282c352\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9ecb7e color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"a9ecb7e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>To control the airflow in the lab as well as transferring the machine into the lab, a few points must be followed. To transport the large machines to the lab for installation, proceed as follows (in some cases it is needed to lean back and transport the machine to the lab, and then unpack it):<\/p><p style=\"padding-left: 40px;\">The laboratory need to have a special gate for transporting large machines (the gate should be designed as per the machine height and transportation method). Otherwise, the entrance gate must be designed as two-piece (there should be a window on upper part of the main door stretched to the roof that can be opened easily with no hindrance)<\/p><p style=\"padding-left: 40px;\">The main door of the lab should open outward<\/p><p style=\"padding-left: 40px;\">To control temperature and heat uniformity, energy efficient and high performance doors and windows must be used<\/p><p style=\"padding-left: 40px;\">There should be no damper and obstacle on the floor (specially at entrances)<\/p><p style=\"padding-left: 40px;\">Rigid hooks must be welded on the roof for installation of overhead crane (max. capacity 2t)<\/p><\/div><div id=\"simple-translate\" class=\"simple-translate-system-theme\"><div><div class=\"simple-translate-button isShow\" style=\"background-image: url('moz-extension:\/\/2a018086-adaf-46b0-898b-c31f51ce5d0e\/icons\/512.png'); height: 22px; width: 22px; top: 4px; left: 53px;\">\u00a0<\/div><div class=\"simple-translate-panel \" style=\"width: 300px; height: 200px; top: 0px; left: 0px; font-size: 13px;\"><div class=\"simple-translate-result-wrapper\" style=\"overflow: hidden;\"><div class=\"simple-translate-move\" draggable=\"true\">\u00a0<\/div><div class=\"simple-translate-result-contents\"><p class=\"simple-translate-result\" dir=\"auto\">\u00a0<\/p><p class=\"simple-translate-candidate\" dir=\"auto\">\u00a0<\/p><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-1cfb457 e-flex e-con-boxed e-con e-parent\" data-id=\"1cfb457\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-22007d1 wd-width-100 elementor-widget elementor-widget-wd_title\" data-id=\"22007d1\" data-element_type=\"widget\" data-widget_type=\"wd_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"title-wrapper wd-set-mb reset-last-child wd-title-color-default wd-title-style-default wd-title-size-default text-center\">\n\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h4 class=\"woodmart-title-container title wd-fontsize-l\"> list of important points for the design of the laboratory is presented as follows<\/h4> \n\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-cf2ec05 e-flex e-con-boxed e-con e-parent\" data-id=\"cf2ec05\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-5b65fe0 e-con-full e-flex e-con e-child\" data-id=\"5b65fe0\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-e539e59 e-grid e-con-full e-con e-child\" data-id=\"e539e59\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-89ef48d elementor-widget elementor-widget-heading\" data-id=\"89ef48d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Laboratory Entrance and Device Transportation<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d0b5908 e-grid e-con-full e-con e-child\" data-id=\"d0b5908\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3bb258d color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"3bb258d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>To control the airflow in the lab as well as transferring the machine into the lab, a few points must be followed. To transport the large machines to the lab for installation, proceed as follows (in some cases it is needed to lean back and transport the machine to the lab, and then unpack it):<\/p><p style=\"padding-left: 40px;\">The laboratory need to have a special gate for transporting large machines (the gate should be designed as per the machine height and transportation method). Otherwise, the entrance gate must be designed as two-piece (there should be a window on upper part of the main door stretched to the roof that can be opened easily with no hindrance)<\/p><p style=\"padding-left: 40px;\">The main door of the lab should open outward<\/p><p style=\"padding-left: 40px;\">To control temperature and heat uniformity, energy efficient and high performance doors and windows must be used<\/p><p style=\"padding-left: 40px;\">There should be no damper and obstacle on the floor (specially at entrances)<\/p><p style=\"padding-left: 40px;\">Rigid hooks must be welded on the roof for installation of overhead crane (max. capacity 2t)<\/p><\/div><div id=\"simple-translate\" class=\"simple-translate-system-theme\"><div><div class=\"simple-translate-button isShow\" style=\"background-image: url('moz-extension:\/\/2a018086-adaf-46b0-898b-c31f51ce5d0e\/icons\/512.png'); height: 22px; width: 22px; top: 4px; left: 53px;\">\u00a0<\/div><div class=\"simple-translate-panel \" style=\"width: 300px; height: 200px; top: 0px; left: 0px; font-size: 13px;\"><div class=\"simple-translate-result-wrapper\" style=\"overflow: hidden;\"><div class=\"simple-translate-move\" draggable=\"true\">\u00a0<\/div><div class=\"simple-translate-result-contents\"><p class=\"simple-translate-result\" dir=\"auto\">\u00a0<\/p><p class=\"simple-translate-candidate\" dir=\"auto\">\u00a0<\/p><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"wd-negative-gap elementor-element elementor-element-7f7c2cf e-flex e-con-boxed e-con e-parent\" data-id=\"7f7c2cf\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-589689d e-con-full e-flex e-con e-child\" data-id=\"589689d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-5259a0e e-grid e-con-full e-con e-child\" data-id=\"5259a0e\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-31eefa3 elementor-widget elementor-widget-heading\" data-id=\"31eefa3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Wiring\/Cabling and Safety Rules<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-51eb2cf e-grid e-con-full e-con e-child\" data-id=\"51eb2cf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-811bc39 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"811bc39\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Power wiring of the lab should be void of faulty earthing and power cut-off<\/p><p>The laboratory earthing should be independent, and specifically designed for the lab. No miscellaneous use is allowed<\/p><p>The lab power should be separate from the factory power source as far as possible in order to have less noises due to the operation of other devices in the production line<\/p><p>A separate electrical panel must be installed at the lab entrance gate, proper circuit breakers for each device must be installed (amp, slow-blow, fast-blow) to prevent power cut-off in the lab<\/p><p>An emergency switch must be intended to prevent power cut-off of the lab in case of emergencies<\/p><p>Use experts and advisors in this regard<\/p><p>Isolation transformer, stabilizer and proper UPS must be used and installed at the lab entrance (recommended) to supply electricity and avoid fluctuation and noise<\/p><p>Installing firefighting cylinders outside the lab in proper places at reach<\/p><p>It is recommended to install fire alarm system<\/p><p>Wiring and cabling for power and internet must be available.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d02c790 e-con-full e-flex e-con e-child\" data-id=\"d02c790\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-a4047d0 e-grid e-con-full e-con e-child\" data-id=\"a4047d0\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59584b5 elementor-widget elementor-widget-heading\" data-id=\"59584b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Sewage<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-329fe0e e-grid e-con-full e-con e-child\" data-id=\"329fe0e\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b2c965 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"8b2c965\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Regarding the machine requirements for water inlet and outlet, a sewage system must be intended next to the machine<\/p><p>Lab floor should have drain holes<\/p><\/div><div id=\"simple-translate\" class=\"simple-translate-system-theme\"><div><div class=\"simple-translate-button isShow\" style=\"background-image: url('moz-extension:\/\/2a018086-adaf-46b0-898b-c31f51ce5d0e\/icons\/512.png'); height: 22px; width: 22px; top: 139px; left: 212px;\">\u00a0<\/div><div class=\"simple-translate-panel \" style=\"width: 300px; height: 200px; top: 0px; left: 0px; font-size: 13px;\"><div class=\"simple-translate-result-wrapper\" style=\"overflow: hidden;\"><div class=\"simple-translate-move\" draggable=\"true\">\u00a0<\/div><div class=\"simple-translate-result-contents\"><p class=\"simple-translate-result\" dir=\"auto\">\u00a0<\/p><p class=\"simple-translate-candidate\" dir=\"auto\">\u00a0<\/p><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-681ee58 e-con-full e-flex e-con e-child\" data-id=\"681ee58\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-dc19339 e-grid e-con-full e-con e-child\" data-id=\"dc19339\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3395760 elementor-widget elementor-widget-heading\" data-id=\"3395760\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Compressed Air<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-70c10fb e-grid e-con-full e-con e-child\" data-id=\"70c10fb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1516c5c color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"1516c5c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>In case of need to compressed air, metal piping must be conducted to supply compressed air to the lab<\/p><p>Air Service Unit comprising filter, lubricator, and regulator must be near the machine<\/p><p>Using silent air compressors next to the machine is allowable<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b553889 e-con-full e-flex e-con e-child\" data-id=\"b553889\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-7221706 e-grid e-con-full e-con e-child\" data-id=\"7221706\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3a3805 elementor-widget elementor-widget-heading\" data-id=\"f3a3805\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Working Temperature and Humidity<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-586c64b e-grid e-con-full e-con e-child\" data-id=\"586c64b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-372f9b8 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"372f9b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Temperature of the lab environment should be strictly controlled<\/p><p>Heating and cooling system with uniform distribution inside the lab environment is recommended<\/p><p>Installing proper air conditioning system proportional to the lab space is mandatory<\/p><p>Working humidity 1%-10%<\/p><p>Sensors, as well as temperature and humidity gauges must be installed in the laboratory<\/p><p>Isolation room (pre-entrance) must be available<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eac538f e-con-full e-flex e-con e-child\" data-id=\"eac538f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-8fccf23 e-grid e-con-full e-con e-child\" data-id=\"8fccf23\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-27715a8 elementor-widget elementor-widget-heading\" data-id=\"27715a8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Foundation and Walls<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ab7bc1f e-grid e-con-full e-con e-child\" data-id=\"ab7bc1f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c14f813 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"c14f813\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Lab floor and walls should be designed as per covering, absorption, and vibration standards<\/p><p>Floor must be designed so that the vibration caused by different units and external factors, have the least effect on it<\/p><p>There should the possibility of execution of foundation for the machines (bolts are tightened to the ground)<\/p><p>Proper ceramic tiles, and stone slabs must be selected for flooring and walls proportional to the lab conditions<\/p><p>Lab floor must be easily cleaned and washed<\/p><p>Walls should be rigid enough to install cabinets and shelves<\/p><p>No rodents, birds and insects are allowed to enter the laboratory, they may cause equipment malfunction and damage<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6d2b737 e-con-full e-flex e-con e-child\" data-id=\"6d2b737\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-7fb3645 e-grid e-con-full e-con e-child\" data-id=\"7fb3645\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e92962 elementor-widget elementor-widget-heading\" data-id=\"4e92962\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Wardrobe and Shelves for Keeping Tools and Things<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fdc5297 e-grid e-con-full e-con e-child\" data-id=\"fdc5297\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a2caf62 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"a2caf62\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Some machines have accessories that need to be stored in a suitable space near the machine<\/p><p>Metal shelves for heavy tools and accessories<\/p><p>Cabinets and wardrobe for keeping light tools and accessories<\/p><p>Bookshelf for keeping manuals, user guides, \u2026<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-36fd9c1 e-con-full e-flex e-con e-child\" data-id=\"36fd9c1\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-7200848 e-grid e-con-full e-con e-child\" data-id=\"7200848\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c56ee7 elementor-widget elementor-widget-heading\" data-id=\"0c56ee7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Machine and PC Tables<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f4aef11 e-grid e-con-full e-con e-child\" data-id=\"f4aef11\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7a9bf5 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"a7a9bf5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Some machines are placed on tables, and some need PC tables<\/p><p>For table machines, proportional to its height and weight, a rigid and robust table must be made<\/p><p>The table should not be too high so that the operator can perform the test easily<\/p><p>In case of need to PC, a separate table should be designed and made as per the current standards and placed on the right side of the machine<\/p><\/div><div id=\"simple-translate\" class=\"simple-translate-system-theme\"><div><div class=\"simple-translate-button isShow\" style=\"background-image: url('moz-extension:\/\/2a018086-adaf-46b0-898b-c31f51ce5d0e\/icons\/512.png'); height: 22px; width: 22px; top: 108px; left: 194px;\">\u00a0<\/div><div class=\"simple-translate-panel \" style=\"width: 300px; height: 200px; top: 0px; left: 0px; font-size: 13px;\"><div class=\"simple-translate-result-wrapper\" style=\"overflow: hidden;\"><div class=\"simple-translate-move\" draggable=\"true\">\u00a0<\/div><div class=\"simple-translate-result-contents\"><p class=\"simple-translate-result\" dir=\"auto\">\u00a0<\/p><p class=\"simple-translate-candidate\" dir=\"auto\">\u00a0<\/p><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1c3d705 e-con-full e-flex e-con e-child\" data-id=\"1c3d705\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-710fac7 e-grid e-con-full e-con e-child\" data-id=\"710fac7\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-889e9da elementor-widget elementor-widget-heading\" data-id=\"889e9da\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Equipment Layout<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d0fd79e e-grid e-con-full e-con e-child\" data-id=\"d0fd79e\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9526884 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"9526884\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p>Machines should be installed and arranged based on the equipment layout prepared by the manufacturer. Some machines are not displaced after installation (i.e. fixed mount machines)<\/p><p>Some devices are placed on the table, thus proper table should be made proportional to the lab space. Weight, dimensions, and operation should be taken into account; table is generally placed on the right side of the machine<\/p><p>Floor standing machines do not need tables, these machines should be installed and leveled on the floor or foundation based on the manufacturer instructions<\/p><p>Allocate extra space for unforeseen conditions<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8487f34 e-con-full e-flex e-con e-child\" data-id=\"8487f34\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-849a68c e-grid e-con-full e-con e-child\" data-id=\"849a68c\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6417b5e elementor-widget elementor-widget-heading\" data-id=\"6417b5e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">A Few Laboratory Infrastructure Requirements<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c254394 e-grid e-con-full e-con e-child\" data-id=\"c254394\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f0112c8 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f0112c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div dir=\"ltr\"><p><strong>Walls and roofs<\/strong>: made of insulated sandwich panels (heat and cold resistant, sound proofing, moisture resistant)<\/p><p><strong>Doors<\/strong>: made of HDF, resistant against humidity, sound proofing; equipped with smart controller and electronic lock<\/p><p><strong>Air<\/strong> <strong>Conditioning<\/strong> <strong>System<\/strong>: ducted heating and cooling system, capable of creating simultaneous and controlled blowing and suction<\/p><p><strong>Floor<\/strong>: epoxy or polyurethane floor covering (integral and seamless), impenetrable to liquids<\/p><p><strong>Lighting<\/strong> <strong>system<\/strong>: cold lighting system with uniformity through the whole salon with various stands<\/p><p><strong>Wiring<\/strong>: special safe wiring, electrical panel, as well as predicting the power consumption<\/p><p><strong>Sewage<\/strong>: special piping and sewage system, hygienic with no leakage, and microbiologically safe<\/p><p><strong>Cabinet,<\/strong> <strong>wardrobe,<\/strong> <strong>and<\/strong> <strong>shelf<\/strong>: should be made of MDF panels with high-durability hinges, in different colors proportional to the lab atmosphere<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Laboratory Construction Requirements To construct a laboratory, a few important points must be considered to follow the equipment layout in<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-30025","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/pages\/30025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/comments?post=30025"}],"version-history":[{"count":46,"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/pages\/30025\/revisions"}],"predecessor-version":[{"id":58176,"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/pages\/30025\/revisions\/58176"}],"wp:attachment":[{"href":"https:\/\/www.santamco.ir\/en\/wp-json\/wp\/v2\/media?parent=30025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}